Back to Build/check report for BioC 3.18:   simplified   long
ABCDEFG[H]IJKLMNOPQRSTUVWXYZ

This page was generated on 2023-06-06 11:00:33 -0000 (Tue, 06 Jun 2023).

HostnameOSArch (*)R versionInstalled pkgs
kunpeng2Linux (openEuler 22.03 LTS-SP1)aarch644.3.0 (2023-04-21) -- "Already Tomorrow" 4366
Click on any hostname to see more info about the system (e.g. compilers)      (*) as reported by 'uname -p', except on Windows and Mac OS X

BUILD results for hca on kunpeng2


To the developers/maintainers of the hca package:
- Allow up to 24 hours (and sometimes 48 hours) for your latest push to git@git.bioconductor.org:packages/hca.git to reflect on this report. See Troubleshooting Build Report for more information.

- Use the following Renviron settings to reproduce errors and warnings.

Note: If "R CMD check" recently failed on the Linux builder over a missing dependency, add the missing dependency to "Suggests" in your DESCRIPTION file. See the Renviron.bioc for details.

raw results

Package 900/2199HostnameOS / ArchINSTALLBUILDCHECKBUILD BIN
hca 1.9.0  (landing page)
Martin Morgan
Snapshot Date: 2023-06-05 06:35:06 -0000 (Mon, 05 Jun 2023)
git_url: https://git.bioconductor.org/packages/hca
git_branch: devel
git_last_commit: 4dff334
git_last_commit_date: 2023-04-25 15:27:02 -0000 (Tue, 25 Apr 2023)
kunpeng2Linux (openEuler 22.03 LTS-SP1) / aarch64  OK    ERROR  skipped

Summary

Package: hca
Version: 1.9.0
Command: /home/biocbuild/R/R-4.3.0/bin/R CMD build --keep-empty-dirs --no-resave-data hca
StartedAt: 2023-06-05 12:08:20 -0000 (Mon, 05 Jun 2023)
EndedAt: 2023-06-05 12:10:32 -0000 (Mon, 05 Jun 2023)
EllapsedTime: 132.2 seconds
RetCode: 1
Status:   ERROR  
PackageFile: None
PackageFileSize: NA

Command output

##############################################################################
##############################################################################
###
### Running command:
###
###   /home/biocbuild/R/R-4.3.0/bin/R CMD build --keep-empty-dirs --no-resave-data hca
###
##############################################################################
##############################################################################


* checking for file ‘hca/DESCRIPTION’ ... OK
* preparing ‘hca’:
* checking DESCRIPTION meta-information ... OK
* installing the package to build vignettes
* creating vignettes ... ERROR
--- re-building ‘hca_manifest_vignette.Rmd’ using rmarkdown
--- finished re-building ‘hca_manifest_vignette.Rmd’

--- re-building ‘hca_vignette.Rmd’ using rmarkdown

Quitting from lines 290-294 [unnamed-chunk-21] (hca_vignette.Rmd)
Error: processing vignette 'hca_vignette.Rmd' failed with diagnostics:
In row 6, can't recycle input of size 35 to size 18.
--- failed re-building ‘hca_vignette.Rmd’

SUMMARY: processing the following file failed:
  ‘hca_vignette.Rmd’

Error: Vignette re-building failed.